undefined
+
  • undefined

HP-DC1210-09 120W DC CCTV Power Supply Box


HP-DC1210-94 series 120W DC CCTV power supply boxes are independently developed by Shenzhen Hynapower Technology Co., Ltd. 115VAC or 230VAC input , 12Vdc, 9 channels total 10A output,  comply with EN61000-3-2 standard.

HP-DC1210-09 is iron shell, which is sturdy and reliable and could improves the heat dissipation effect of the whole power supply box. The efficiency is as high as 85% or more. Under air circulation conditions, the power supply can work at an ambient temperature of -10℃ to +40℃. Perfect solutions for CCTV systems.

Catalog:

DC Power Boxes

Keyword:

HP-DC1210-09 120W DC CCTV Power Supply Box

Product Features

  • Input:115〜264VAC(optional)
  • Output: 12V
  • Output max power:120W
  • Universal input voltage
  • short-circuit/overload, over-voltage/over-temperature protection
  • High reliability, high efficiency
  • Natural cool
  • 100% full load aging test
  • Comply with UL508 (industrial control equipment) certification standards
  • N61000-6-2(EN50082-2)Industrial immunity
  • Work temperature:-10〜40℃
  • MTBF50000 hours
  • EMI:FCC Part 15. CISPR(EN55022) class A
  • EMS:EN61000-4-2(ESD),EN61000-4-3(RS)
  • EN61000-4-4(EFT),EN61000-4-5(Surge)
  •  EN61000-4-6(CS),EN61000-4-6(Common mode conduction)
  • Warranty:2years

Product Specifications

Input Specification

Project

Specifications

Remarks

Input Voltage Range

115-264Vac (optional)

 

Input Frequency Range

47Hz~63Hz

 

Input Current

<3A/115Vac

<1.5A/230Vac

 

Inrush Current

60A/115Vac 60A/220Vac

Cold Start Condition

Efficiency

≥87%

Rated Voltage; Full Load

Power Factor

/

 

 

Output Specification

Model

HP-DC1210-09

Output Voltage

12V

Output Current Range

0~10A

Voltage Accuracy

± 2.0%

Output Power

120W

Source Regulation

± 1.5%

Load Regulation

± 1%

Ripple Noise

<200mV

Efficiency

≥87% typ.

Minimum Load During Test

10% of full load power

Test Conditions

20MHz bandwidth, a 10uF electrolytic capacitor and a 0.1uF polyester capacitor are connected in parallel at the load end for testing

 

Safety Requirements

Insulation Strength and Insulation Resistance

 

Project

Specifications

Insulation Strength*

Insulation Resistance**

Input-----Output

3.00KVac

≥100MΩ

Input-----Ground

2.0KVac

≥100MΩ

Output-----Ground

0.5KVac

≥100MΩ

Remarks

*Indicates withstand voltage level (V); allowable maximum leakage current (mA). **Test conditions: Test voltage is 500VDC, 90%RH.

Leakage Current

2mA<240VAC

Project

Specifications

110Vac

/

220Vac

 

Ordering Information