HP-P250PDS 250W Power Board
HP-P250PDS is a dual voltage output built-in power board which is independently developed by Shenzhen Hynapower Technology Co., Ltd., 90Vac to 260Vac full voltage range AC input. CH1, CH2 output is isolated to ground.
Catalog:
Open-Frame Power Supplies
Keyword:
HP-P250PDS 250W Power Board
Product Features
- Input:90〜260VAC
- Output:CH1:52V; CH2:5V &12V
- Output max power:250W(Fan cooling)
- Universal input voltage
- short-circuit/overload, over-voltage/over-temperature protection
- High reliability, high efficiency, LEVEL VI
- Built-in active PFC
- AC input lightning protection 6KVA
- 100% full load aging test
- Work temperature:-10〜35℃
- MTBF50000 hours
- EMI:FCC Part 15. CISPR(EN55032) class A
- EMS:EN61000-4-2(ESD),EN61000-4-3(RS)
- EN61000-4-4(EFT),EN61000-4-5(Surge)
- EN61000-4-6(CS),EN61000-4-6(Common mode conduction)
- Warranty:2years
Product Specifications
|
Input Specification |
||||||
|
Project |
Specifications |
Remarks |
||||
|
Input Voltage Range |
90-264Vac |
|
||||
|
Input Frequency Range |
47Hz~63Hz |
|
||||
|
Input Current |
<3.5A |
|
||||
|
Inrush Current |
20A/115Vac 40A/220Vac |
Cold State Conditions |
||||
|
Lightning Strike |
6KVA |
|
||||
|
Efficiency |
≥92% |
230Vac Full Load |
||||
|
Power Factor (Active PFC) |
0.99/100Vac |
Full Load |
||||
|
Output Specification |
||||||
|
Model |
HP-P250PDS-A |
HP-P250PDS-B |
||||
|
Output Channels |
CH1 |
CH2 |
CH1 |
CH2 |
||
|
Output Voltage |
DC 52V |
DC5V |
DC 52V |
DC12V |
||
|
Output Current Range |
0~5A |
0~4A |
0~5A |
0~2A |
||
|
Voltage Accuracy |
± 5.0% |
± 5.0% |
± 5.0% |
± 5.0% |
||
|
Voltage Range |
± 5% |
± 5% |
± 5% |
± 5% |
||
|
Output Power |
250W |
20W |
250W |
12W |
||
|
Source Regulation |
± 1.0% |
± 1.0% |
± 1.0% |
± 1.0% |
||
|
Load Regulation |
± 5% |
± 5% |
± 5% |
± 5% |
||
|
Ripple Noise |
<400mV |
<200mV |
<400mV |
<200mV |
||
|
Efficiency |
≥89% typ. |
≥85% typ. |
≥89% typ. |
≥85% typ. |
||
|
Minimum Load During Test |
10% of Full Load Power |
10% of Full Load Power |
10% of Full Load Power |
10% of Full Load Power |
||
|
Test Conditions |
20MHz bandwidth, a 10uF electrolytic capacitor and a 0.1uF polyester capacitor are connected in parallel at the load end for testing |
|||||
|
Safety Requirements |
||||||
|
Insulation Strength and Insulation Resistance |
|
|||||
|
Project |
Specifications |
|||||
|
Insulation Strength* |
Insulation Resistance** |
|||||
|
Input-----Output |
3.00KVac 5ma |
≥100MΩ |
||||
|
Input-----Ground |
2.0KVac 5ma |
≥100MΩ |
||||
|
Output-----Ground |
0.5KVac 5ma |
≥100MΩ |
||||
|
Remarks |
*Indicates withstand voltage level (V); maximum allowable leakage current (mA). **Test conditions: Test voltage is 500VDC, 90%RH. |
|||||
|
Leakage Current |
|
|||||
|
Project |
Specifications |
|||||
|
264Vac |
<3.5mA |
|||||
Ordering Information
| Product Model | |
| HP-P250PDS-A | Industrial Power Supply, CH1: 52V, 5A output, CH2: 5V, 5A |
| HP-P250PDS-B | Industrial Power Supply, CH1: 52V, 5A output, CH2: 12V, 2A |
Product Inquiry