undefined
+
  • undefined

HP-2DC2U500 UPS Access Control Power Supply Box


HP-2DC2U500 is a 500W aluminum UPS access control power supply box, it is independently developed by Shenzhen Hynapower Technology Co., Ltd. 115VAC or 230VAC input, supports 12Vdc and 24Vdc dual-voltage  output, comply with EN61000-3-2 standards.

HP-2DC2U500 is iron shell, which is sturdy and reliable and could improves the heat dissipation effect of the whole power supply box. The efficiency is as high as 85% or more. Under the air circulation condition, the power supply box can work in the ambient temperature of -10℃ to +40℃, perfect solutions for security CCTV systems.

Catalog:

DC Power Boxes

Keyword:

HP-2DC2U500 UPS Access Control Power Supply Box

Product Features

 

  • Input:230VAC
  • Output: 12V and 24V
  • Output max power:500W
  • UPS Charger
  • short-circuit/overload, over-voltage/over-temperature protection
  • High reliability, high efficiency
  • Natural cool
  • 100% full load aging test
  • Comply with UL508 (industrial control equipment) certification standards
  • N61000-6-2(EN50082-2)industrial control equipment
  • Work temperature:-10〜40℃
  • MTBF50000 hours
  • EMI:FCC Part 15. CISPR(EN55022) class A
  • EMS:EN61000-4-2(ESD),EN61000-4-3(RS),
  • EN61000-4-4(EFT),EN61000-4-5(Surge),
  •  EN61000-4-6(CS),EN61000-4-6(Common mode conduction)
  • Warranty:2 years

 

Product Specifications

Input Specification

Project

Specifications

Remarks

Input Voltage Range

180-264Vac

 

Input Frequency Range

47Hz~63Hz

 

Input Current

<8A/115Vac

<4A/230Vac

 

Inrush Current

60A/115Vac 60A/220Vac

Cold Start Condition

Efficiency

≥85%

Rated Voltage; Full Load

Power Factor

/

 

 

Output Specification

Model

HP-2DC2U500

 

Output Voltage

DC12V

DC24V

Output Current Range

0~10A

0~14.5A

Voltage Accuracy

± 2.0%

± 2.0%

UPS Charging

13.8V@2A

24.6V@2A

Output Power

120W

350W

Source Regulation

± 1.5%

± 1.5%

Load Regulation

± 1%

± 1%

Ripple Noise

<200mV

<200mV

Efficiency

≥85% typ.

≥85% typ.

Minimum Load During Test

10% of Full Load Power

10% of Full Load Power

Test Conditions

20MHz bandwidth, a 10uF electrolytic capacitor and a 0.1uF polyester capacitor are connected in parallel at the load end for testing

 

Safety Requirements

Insulation Strength and Insulation Resistance

 

Project

Specifications

Insulation Strength*

Insulation Resistance**

Input-----Output

3.00KVac

≥100MΩ

Input-----Ground

2.0KVac

≥100MΩ

Output-----Ground

0.5KVac

≥100MΩ

Remarks

*Indicates withstand voltage level (V); allowable maximum leakage current (mA). **Test conditions: Test voltage is 500VDC, 90%RH.

Project

Specifications

Leakage Current

2mA<240VAC

 

Ordering Information

Product Inquiry

If you want to inquire about our products, please fill out the form below, and we will contact you as soon as possible!