undefined
+
  • undefined

HP2412 DC to DC Power Converter


HP2412 is a 12W power converter which is independently developed by Shenzhen Hynapower Technology Co., Ltd. DC8-24V  input, 12Vdc 1A output, comply with EN61000-3-2 standard.

HP2412 adopts modular design, compact and beautiful, and the efficiency is as high as 80% or more. Under the condition of air circulation, the whole series can work in the ambient temperature of -10℃ to +40℃, which is a perfect solution for CCTV Systems.

Catalog:

DC-DC Power Supplies

Keyword:

HP2412 DC to DC Power Converter

Product Features

  • Input:DC8-24V
  • Output: 12V
  • Output max power:12W
  • short-circuit/overload, over-voltage/over-temperature protection
  • High reliability, high efficiency
  • 100% full load aging test
  • Comply with UL508 (industrial control equipment) certification standards
  • N61000-6-2(EN50082-2)Industrial immunity
  • Work temperature:-10〜40℃
  • MTBF50000 hours
  • EMI:FCC Part 15. CISPR(EN55022) class A
  • EMS:EN61000-4-2(ESD),EN61000-4-3(RS),
  • EN61000-4-4(EFT),EN61000-4-5(Surge),
  • EN61000-4-6(CS),EN61000-4-6(Common mode conduction)
  • Warranty:2 years

Product Specifications

Input Specification

Project

Specifications

Remarks

Input Voltage Range

8-24Vdc

 

Input Frequency Range

47Hz~63Hz

 

Input Current

<1A/24Vdc

 

Efficiency

≥80%

Rated Voltage; Full Load

Power Factor

/

 

 

Output Specification

Model

HP2412

Output Voltage

12V

Output Current Range

0~1A

Voltage Accuracy

± 1.0%

Output Power

12W

Source Regulation

± 1%

Load Regulation

± 1%

Ripple Noise

<200mV

Efficiency

≥80% typ.

Minimum Load during Test

10% of full load power

Test Conditions

20MHz bandwidth, a 10uF electrolytic capacitor and a 0.1uF polyester capacitor are connected in parallel at the load end for testing

 

Safety Requirements

Insulation Strength and Insulation Resistance

 

Project

Specifications

Insulation Strength*

Insulation Resistance**

Input-----Output

/

≥100MΩ

Remarks

*Indicates withstand voltage level (V); allowable maximum leakage current (mA). **Test conditions: Test voltage is 500VDC, 90%RH.

Leakage Current

/

Project

Specifications

110Vac

/

220Vac

 

Ordering Information